• 220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester
  • 220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester
  • 220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester
  • 220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester
  • 220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester
  • 220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester

220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester

Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Installation: Parallel Arrester
Samples:
US$ 90/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester pictures & photos
220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester
US $85-90 / Piece
Min. Order: 1 Piece
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
TBP
Application
Substation
Size
Meidum
Operation Voltage
High Voltage
Shape
Gyro Type
Material
ZnO
Certification
ISO9001, CCC
Brand
Chsh
Transport Package
Wooden Carton
Specification
Customized
Trademark
CHSH
Origin
China
Production Capacity
200 Piece

Packaging & Delivery

Package Size
100.00cm * 100.00cm * 100.00cm
Package Gross Weight
100.000kg

Product Description

TBP three-phase combined overvoltage protector

Overview
Three-phase combined overvoltage protector (three-phase combined surge arrester) is used to protect the insulation of electric equipment from overvoltage hazards of the protection of electrical appliances, is a new type of surge arrester, which is characterized by limiting the overvoltage between the phase and the ground at the same time, but also effectively limit the overvoltage between the phases, which is not possible to do with ordinary surge arrester. It is widely used to protect vacuum switches, rotating motors, shunt compensation capacitors, power plants, substations and so on. This combination protector adopts large-capacity zinc oxide resistor as the main component inside, which has good volt-ampere characteristics and over-voltage absorption ability, and can provide reliable protection for the protection equipment, which is very popular with the electric power system.

Execution standard
This product implements the national standard GB11032-2000 "AC non-gap metal-oxide surge arrester", JB/T10496-2005 "AC three-phase combined non-gap metal-oxide surge arrester", ZBK49005-90 "AC system with series gap metal-oxide surge arrester", JB/T8459-1996 "surge arrester product modeling method".

Structural features
1,The structure is novel and unique, with four-element star connection, excellent technical performance, high voltage insulation, and greatly utilizing and reducing the use of space;
2,The composite jacket is molded as a whole, with good sealing, explosion-proof, moisture-proof performance, anti-leakage marks, anti-electro-erosion, dirt-resistant, and good water repellency;
3,High-voltage cable wiring to ensure insulation strength and flexible installation;
4,Small volume, light weight, save space, especially suitable for installation in a variety of switchgear (the company's product design is unique, can be installed vertically, can also be installed horizontally.)

Use conditions
1,Altitude not greater than 2000M;
2,Ambient temperature: -40ºC~+40ºC;
3,Power frequency: 48Hz~62Hz;
4, long-term applied to the protector of the industrial frequency voltage does not exceed the protector's continuous operation voltage;
5,Maximum wind speed does not exceed 35m/s;
6, seismic rupture degree 7 degrees and the following areas;

Use selection
Three-phase combined overvoltage protector is divided into gapless type and series gap type, the use of the difference is: gapless overvoltage protector, as long as the system has an overvoltage, can be well absorbed and suppressed; and gap-type overvoltage protector, only the overvoltage on the system energy reaches the overvoltage protector to break through the series gap in the overvoltage protector and discharge, gap-type overvoltage protector will be acted upon.
Therefore, it is recommended that users in the selection of: regular selection of non-gap type over-voltage protector, the system disturbing voltage is too large or the switch frequently close the place to choose a gap type over-voltage protector is appropriate.

220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester
220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester pictures & photos
220kv Tbp Three-Phase Six-Column Combined Overvoltage Protector Zinc Oxide Arrester
US $85-90 / Piece
Min. Order: 1 Piece
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
105080000 RMB
Plant Area
12000 square meters